Menü überspringen

EXE 600 Series

Request

Documentation

undefinedProduct Information

Specifications

EXE 602 E

EXE 660 B

Input

11 µAPP

Electrical Connection

M23 flange socket (female) 9-pin

Cable length

≤ 30 m for IEncoder ≤ 120 mA

Interpolation1)

Without, 5-fold

25-fold, 50-fold, 100-fold, 200-fold, 400-fold

Input frequency1) for interpolation

Nominal values2)

Without

50 kHz

5-fold

25 kHz

25-fold

50 kHz

50 kHz

25 kHz

12.5 kHz

50-fold

50 kHz

25 kHz

12.5 kHz

6.25 kHz

100-fold

25 kHz

12.5 kHz

6.25 kHz

3.12 kHz

200-fold

12.5 kHz

6.25 kHz

3.12 kHz

1.56 kHz

400-fold

6.25 kHz

3.12 kHz

1.56 kHz

0.78 kHz

Output

  TTL (unclocked)

TTL (clocked)

Electrical connection

M23 flange socket (male) 12-pin

Cable length

≤ 100 m (Uas ≤ 50 m)

Edge separation a

≥ 2.500 µs

≥ 0.500 µs

≥ 0.075 µs

≥ 0.175 µs

≥ 0.370 µs

≥ 0.760 µs

Reference mark signal1)

Pulse width 90° elec. or ungated (only when without interpolation) or 270° elec.

Fault indication1)

through fault detection signal Uas or, in addition, Ua1/Ua2 high impedance

Power supply

5 V ± 5%

Current consumption3)

≤ 90 mA

≤ 120 mA

Operating temperature

Storage temperature

0 °C to 70 °C

–30 °C to 80 °C

Vibration 50 to 2000 Hz

Shock 11 ms

≤ 10 m/s2

≤ 300 m/s2

Protection

IP 65

Weight

0.7 kg

Bold: These preferred versions are available on short notice

1) Adjustable

2) The actual input frequency can be up to 5 % lower. Exceeding this limit results in failure

3) Not including the current consumption of the encoder (see the corresponding brochure) and without output load
(80 mA with recommended input circuitry)